Cast-iron AGAs and heavy range cookers dismantled and removed.

In short

AGA and Range Cooker Removal is the dismantling and removal of heavy cast-iron heat-storage cookers such as AGA, Rayburn, Esse and Stanley, plus large modern range cookers. Specialists disconnect the fuel supply, take the cooker apart section by section, remove the insulation, carry out the cast-iron parts and recycle or reuse them.

  • Free, no-obligation quotes
  • Vetted, insured specialists
  • Clear fixed prices

Free AGA and Range Cooker Removal quote

No obligation. We only use your details to reply about this job.

A traditional two-oven AGA weighs around 400 kg, and a four-oven model considerably more. It does not come out in one piece. It has to be stripped down on site into its hotplates, lids, oven castings, barrel and outer panels, with the loose insulation vacuumed out as each section comes away. We arrange AGA and range cooker removal across the UK through vetted, insured specialists who do this work regularly and know the difference between a 1970s solid-fuel model and a modern electric one.

Our teams remove AGAs, Rayburns, Esse, Stanley, Everhot and heavy dual-fuel range cookers from farmhouses, townhouses and holiday lets. They plan for the fuel type, the flue, the insulation and the route out, and leave the alcove swept and ready for a new cooker or units. Cast iron is valuable to recycle, and where an older cooker is suitable for reconditioning we will tell you, because some still have resale value.

How it works

  1. Send details and photos

    Tell us the make, model, number of ovens, fuel type and whether it heats water or radiators. Photos of the cooker, its data badge, the flue and the route out let us plan and price accurately.

  2. Fixed quote and plan

    We confirm a single fixed price, the number of crew, how long the job should take, and which engineer is needed to disconnect the fuel supply. If the cooker may contain asbestos, we recommend testing first.

  3. Disconnection and cooling

    The cooker is switched off at least 24 hours before so the castings are cold. A Gas Safe, OFTEC or electrical engineer isolates and caps the supply, and any boiler circuit is drained.

  4. Dismantling and removal

    The team protects floors, strips the cooker into sections, vacuums insulation, and carries the castings out. A typical two-oven AGA takes three to five hours from start to clean-up.

  5. Clean-up and recycling

    The alcove is swept and vacuumed and the flue covered. Cast iron is recycled or sent for reconditioning, and you receive a waste transfer note for everything removed.

AGA and Range Cooker Removal prices

AGA and range cooker removal is priced on the cooker's size and weight, how much dismantling it needs, the fuel type and the access. A modern range cooker is a short job. A four-oven cast-iron AGA with a boiler and an awkward route can take most of a day. Reconditionable cookers may lower the price.

JobGuide priceNotes
Modern range cooker, 90–110cm£110–£180Three-person team with skates and trolleys; fuel supply must be capped first.
Two-oven AGA dismantle and removal£350–£550Full on-site strip-down, insulation removal, clean-up and cast-iron recycling.
Three or four-oven AGA£450–£750Longer dismantle and more castings to carry; route and access affect price.
Rayburn or Stanley with boiler£350–£600Heating system must be drained and capped by a plumber before work starts.
Fuel disconnection by qualified engineer£75–£150Gas Safe, OFTEC or electrical isolation, depending on the cooker's fuel type.
Asbestos sampling before removalfrom £150Recommended for older cookers or flues of unknown history before any dismantling.

What affects the price →

Who we work for

Homeowners replacing an AGA

Many people switch from an always-on AGA to a modern range or induction hob to cut running costs. We remove the old cooker cleanly and leave the space ready for the new one.

Kitchen designers and builders

Renovation teams can hand the AGA strip-out to us before work starts, saving their crew a dusty, heavy day and keeping the programme on track.

Farmhouses and rural properties

Oil and solid-fuel Rayburns and AGAs are common in rural homes. We coordinate OFTEC technicians, heating engineers and long carries across yards.

Holiday lets and estates

Owners refurbishing cottages or estate houses between seasons need predictable timings, clean working and clear paperwork for their records.

Executors and house buyers

A newly bought or inherited property may come with a cold, unwanted AGA. We assess whether it has resale value and remove it either way.

Rules and standards that apply

  • Disconnecting a gas or LPG-fired AGA or range cooker is gas work and must be done by a Gas Safe registered engineer under the Gas Safety (Installation and Use) Regulations 1998.
  • The Control of Asbestos Regulations 2012 require any work on asbestos-containing materials to be carried out by suitably trained people, and higher-risk work by a licensed contractor; asbestos waste must be disposed of as hazardous waste.
  • Under the Environmental Protection Act 1990 duty of care, you must pass your waste only to a registered waste carrier and should receive a waste transfer note.
  • Electric AGAs and range cookers fall under the WEEE Regulations 2013, so their electrical components must be treated at an authorised facility.

How to choose the right aga and range cooker removal company

  • Ask whether the team has dismantled your specific type of cooker before, such as a solid-fuel Rayburn or a four-oven AGA.
  • Check they hold a waste carrier registration and confirm it on the public register.
  • Confirm who disconnects the fuel supply and that they hold the right registration, such as Gas Safe or OFTEC.
  • Ask how they will handle insulation dust and protect your floors and kitchen.
  • Make sure they raise the question of asbestos for older cookers rather than ignoring it.
  • Get a fixed price that covers dismantling, clean-up, transport and recycling.

Frequently asked questions

How much does it cost to remove an AGA?

Removing a two-oven AGA typically costs £350–£550, including dismantling, insulation removal, clean-up and recycling. Three and four-oven models usually cost £450–£750. Fuel disconnection by a Gas Safe, OFTEC or electrical engineer is extra if not already done. If your cooker can be reconditioned and resold, the removal price may be lower.

How heavy is an AGA cooker?

A traditional two-oven cast-iron AGA weighs around 400 kg, and larger four-oven models weigh considerably more. That is why AGAs are never moved in one piece. They are dismantled on site into hotplates, oven castings and panels, the heaviest of which weigh roughly 50–90 kg and can be carried by two people.

Can an AGA be removed in one piece?

Almost never. An assembled AGA is too heavy and too wide for most doorways, and moving it whole risks floor damage and injury. It was built on site from sections and has to come out the same way. Dismantling also allows the insulation to be removed and bagged properly before the castings are carried out.

How long does AGA removal take?

A two-oven AGA usually takes three to five hours to dismantle, clear and remove. A four-oven model, a Rayburn with a boiler, or a cooker with a long or awkward route can take most of a day. The cooker must be switched off at least 24 hours beforehand so the cast iron is cold enough to handle.

Is my old AGA worth anything?

Possibly. There is a trade in reconditioned AGAs and Rayburns, and a cooker with sound castings, good enamel and all its parts may have resale value. Badly chipped enamel, cracked castings or missing parts reduce this sharply. Send clear photos of the cooker and its data badge and we will give you an honest view.

Do old AGAs contain asbestos?

Some older cast-iron cookers can contain asbestos in rope seals, gaskets, flue pipes or insulation, especially models made several decades ago. Not all do, and you cannot tell by looking. If your cooker or flue is old or its history is unknown, have it sampled by a qualified surveyor before dismantling, so any asbestos is removed safely and legally.

Who disconnects an oil-fired AGA?

Oil-fired AGAs and Rayburns are normally disconnected by an OFTEC-registered technician, who isolates the oil supply and caps the line. Gas and LPG models need a Gas Safe registered engineer, and electric models a competent electrician. We can arrange the right engineer for your cooker so it is safe before dismantling begins.

What happens to the flue when an AGA is removed?

The flue pipe and any register plate are taken down as part of the removal, and the opening into the chimney or wall is temporarily covered. If you plan to install a new range cooker or wood burner, your installer must check whether the existing flue or chimney is suitable for the new appliance before connecting it.

See all FAQs →